PHOTOCELL
RELAYS
|
|
|
|
|
|
|
| Photocell relays
is working accordingly with the principle following
up the day light via a light sensör. Generally are
used to illuminating the gardens, streels, and
shoping places. It works that the switshingon the
illumination device when the sun rise.
Photocell sensor(cell) is montaged in to the acrilic
water and heating protection box, and it's covered
air proof LDR photo resistant, and it changes
accodingly with the light resistance of the located
areahe light lumen is lower than the adjusted value,
the relay will be contacted right after the time
delay. And this delaying time features designed for
protection of sudden, and high lightning. |

|
| FR-10:
Donned with lux (1-10lux) adjustment pod/knob
and fixed 40 sec time delay. |
|
FR-10Z: Equipped with sensing time adjustment
that differs from the FR-10 this sensing time
adjustment verify to adjust sensing time as 0-60 sec. |
|
FR-10ZZ: Donned with working time knob that
differ from the FR-10Z. Adjustable between 1-12
hours. Can be used to work a specific time intevals
in to the darknees. |
|
Working voltage
flour |
: 220 V |
| |
Working
interval |
: (0,8-1,2)xUn |
| |
Working fquenay |
: 50Hz |
| |
Out
contavts |
: 1 Change over
7A, 250V AC |
| |
Histerisis value |
: Min: 5%- Max:
30% |
| |
Warning type |
: Led |
| |
Working
temperature |
: -5ºC
+ 50ºC |
|
Connection
type |
:
In to the panels upright or over rail. |
|
Protection
class |
:
IP 20 |
| |
Light
adjustment |
:
1-10Lux |
|
Delay |
:
40sn. 40 sec |
| |
On
/ off |
:
LDR photo resistance |
| |
Adjusting
tolerance |
:
10 Lux ( 7 Lux - 12 Lux ) |
|
|
|
|
|
|
|